- Browse Categories
-
Energy Storage Series
- EV Chargers
- Ring Main Unit Series
- LBS and Recloser
- High & Low Voltage Complete Series
- Distribution Transformers
- Components
- Distribution Automation Terminal Series
- Digital Platform System
- EV Chargers
- Subscribe
-
Get email updates on new products
- Hot Product
- ExhibitionMore>>
-
-
EP 20 concluded, Comking depicted a new vision of the intelligent and sustainable development of the power world
2020 Shanghai International Electric Power Equipment and Technology Exhibition. It has been successfully concluded on December 5~ -
Dry air insulated switchgear debuted at the Asian Power and Electrical Exhibition
From June 6 to 8, 2016, Comking Electric was invited to participate in the 2016 Asian Power and Electrical and Smart Grid Exhibition.
-
- Contact Us
- Please contact our customer care team for customized services.
Category
-
-
Digital AI Autonomous Operation and Maintenance Management Platform for Power Distribution Facilities
AI-driven autonomous operation and maintenance platform that applies modern information technologies—such as the Internet of Things (IoT), Big Data, Cloud Computing, Digital Twin, and Artificial Intelligence—to digitize and visualize power distribution facilities within electrical rooms.
More
-
-
Generation-Grid-Load-Storage Integrated Platform
Comking Electric's Generation-Grid-Load-Storage Integrated Platform provides users with a convenient, efficient, and secure full-chain energy management solution.
More
-
-
Chinese-type Delivery Substation
Chinese-type delivery substation, commonly referred to as the delivery substation manufactured with national standard. The Chinese-type delivery substation YBF口-40.5/0.69kV is a power equipment that integrates high-voltage switchgear, transformer, and protective fuses in the oil tank, with low-voltage switchgear and corresponding auxiliary equipment.
More
-
-
Low Voltage Integrated Distribution Switchgear
The JP series low-voltage comprehensive distribution switchgear is suitable for transmission and distribution systems with AC 50Hz and rated voltage below 0.4kV.
More
-
-
GGD AC Low-voltage Distribution Switchgear
GGD AC low-voltage distribution switchgear is suitable for AC 50Hz, rated working voltage 380V, rated operating current 1000-3150A distribution systems of power users such as substations, power plants, and industrial and mining enterprises. It is used for energy conversion, distribution, and control of power, lighting, and power generation and distribution equipment.
More
-
-
CXGN-12 Box Type Fixed Indoor Switchgear
The CXGN-12 box type fixed AC metal enclosed switchgear is a high-voltage equipment of the delivery substation independently developed by our company.
More
-
-
CKVB-12 Indoor Vacuum Circuit Breaker
CKVB-12 indoor vacuum circuit breaker is suitable for indoor switchgear of three-phase AC 50Hz and rated voltage 12kV power system. It is suitable for power plants, substations and distribution rooms in power systems, especially in places where frequency operation at rated operating current or multiple switching and closing of short-circuit currents is required.
More
-
-
CKFZ-12 Indoor Vacuum Load Switch
1.Stable insulation performance:Vacuum bubble installed inside the ring network resin insulation cylinder.
More
2.High protection level:Interlocking mechanism, automatically meeting the "five prevention" requirements.
3.Good suitability:Vacuum switch, capable of breaking 20kA short-circuit current, combined with protective devices, can achieve various protection functions.
-
-
CWBC-03 Distribution Automation Feeder Terminal
AC Voltage: 100V, 220V (rated voltage Un); 50Hz.
More
AC Current: 5A, 1A (rated current In); 50Hz.
DC Power Supply: 24V, allowable deviation: ±20%.
Input voltage for switch quantity and status quantity: DC 24V, starting voltage (60%–75%) Ue
-
-
CWBC-02 Distribution Automation Feeder Terminal
AC voltage: 100V, 220V (rated voltage Un); 50Hz.
More
AC current: 5A, 1A (rated current In); 50Hz.
DC Power Supply: 24V, Allowable Deviation: ±20%;
Input Voltage for Switch Quantity and Status Quantity: DC 24V, Starting Voltage (60%–75%)
-
-
CSR010 (Self-Powered) protection device
Rated Specifications: Frequency: 50 Hz/60 Hz (Universal)
More
AC Current: 5 A or 1 A (Universal)
Power Supply: DC 48 V, ±20%
DC24V,±20%
Self-Powered, drawing power from the phase current transformer
-
-
CKTB100 Transformer Smart Terminal
Rated specifications: AC voltage: 100 V or 220 V
More
AC current: 5 A or 1 A
Frequency: 50 Hz
Power Supply: AC 220 (110) V,±20%DC220(110)V,±20%
-
-
CKSK800 Intelligent Operation and Maintenance Measurement and Control Device
Rated Specifications: AC Voltage: 57.73 V (Line Voltage)
More
AC Current: 5 A or 1 A
Frequency: 50 Hz
Power Supply: AC 220 V, ±20%
-
-
CKPM680 Distribution Automation Communication Unit
Direct current power supply: AC220V, DC220V, DC48V, DC24V, Allowable deviation: ±20%
More
Input voltage for switch quantity and status quantity: DC 48V, DC 24V, with starting voltage ( 60%~75% )
Measured current: AC 0A~6A
Zero-sequence current: AC 0A~100A
Alternating current voltage: AC 0V~450V
-
-
CKPM603 Distribution Automation Measurement and Control Unit
15 channels of opto-isolated digital inputs
More
13 channels of AC measurement and 2 channels of DC measurement
6 channels of output, with selectable voltage levels and an optional operation loop function
Device power supply: AC/DC 220V, AC/DC 110V, DC 48V, DC 24V, with an allowable deviation of ± 20%
Input voltage for switching quantities and status quantities: AC/DC 220V, AC/DC 110V, DC 48V, DC 24V, with a starting voltage of ( 60%~75% )
-
-
CKPM602 Distribution Automation Terminal
Maximum support for 16 circuit loop intervals
More
3 channels of remote measurement: IA, IB, IC, or IA, IC, 3I0
6 channels of remote signals: open position, closed position, not stored energy, grounding switch, isolation, standby
2 channels of remote control: trip, close
Voltage and current at 0.2 level, power at 0.5 level, frequency at ±0.01 level
-
-
CKPM502 Boundary Switch Control Device
Rated Specifications: AC Voltage (to be specified at the time of order): 100 V or 220 V
More
AC Current (to be specified at the time of order): 5 A or 1 A
Frequency: 50 Hz
Power Supply (to be specified at the time of order): AC 85 to 264 V
DC100~264V
DC 24 V or DC 48 V, ±20%
-
-
CKEV-DD360 Split Type DC Charger
360kW Split-Type DC Charging System (1 Unit, 3 Terminals, 6 Guns)
More
This series consists of 1 main power cabinet and 3 charging terminals (configurable as either dual-gun or single-gun terminals).
-
-
CKEV-DC60/80 Integrated DC Charger
The 60kW/80kW integrated DC charger integrates the charger, charging interface, human-computer interaction interface, communication, and billing components into a single unit, suitable for outdoor fast DC charging of electric vehicles. It has the capability to safely and automatically charge the battery of electric vehicles to full capacity.
More
-
-
CKEV-DC120 Integrated DC EV Charger (Dual-Gun)
The 120kW dual-gun DC integrated charger is an advanced charging device specifically designed for rapid charging of electric vehicles. This product integrates efficient charging modules, intelligent control systems, and user-friendly operation interfaces, with the capability to rapidly charge two electric vehicles simultaneously.
More